0.1–0.2 µm Nylon filters
Fine-pore configurations for applications requiring a high level of particulate retention. Where microbial or sterile performance is required, the exact filter grade and validation documentation must be confirmed.
Send a quick request for this configuration. We reply by email.
Filtra International supplies hydrophilic Nylon membrane capsule filters for precision filtration of aqueous solutions, alcohol-containing liquids and compatible process fluids. Available pore sizes range from 0.1 to 3.0 µm, with multiple capsule lengths and connection configurations for laboratory, pilot and process filtration.
Nylon combines natural hydrophilicity with documented alcohol resistance, making it particularly useful where aqueous and alcohol-based liquids need to be filtered using the same general membrane chemistry.
*Configuration note: approximately 300 cm² is documented for the compact Nylon capsule configuration. Filtra also offers larger selectable capsule formats; filtration area and other technical properties vary with the exact capsule size and configuration.
| Filter type | Disposable Nylon membrane capsule filter for liquid filtration |
|---|---|
| Filter membrane | Hydrophilic Nylon |
| Membrane characteristics | Hydrophilic, alcohol resistant and low protein adsorption |
| Media support | Polypropylene |
| Capsule hardware / housing | Polypropylene |
| Optional filling bell | Polycarbonate, configuration-dependent |
| Available pore sizes | 0.1, 0.2, 0.45, 0.65, 1.0 and 3.0 µm |
| Filtra selectable capsule lengths | 1.5", 2.5", 5", 10" and 20" |
| Compact configuration filter area | Approx. 300 cm² |
| Compact configuration maximum working pressure | 5 bar at 20 °C |
| Documented maximum operating temperature | 80 °C |
| Integrity testing | 100% integrity tested for the documented compact capsule range |
| Biological safety | Documented components meet USP Class VI-121°C specifications for plastics |
| Hot-water sanitisation | 90 °C for 30 minutes, multiple cycles |
| Autoclaving | 121 °C for 30 minutes, multiple cycles for the documented compact configuration |
| Material compliance | Documented FDA 21 CFR and EU 10/2011 food-contact material compliance |
Process liquid enters the capsule through the selected inlet connection and passes through the Nylon membrane. The controlled membrane pore structure retains particulate contamination according to the selected pore-size rating, while filtered liquid exits through the outlet connection.
The membrane and housing form one enclosed disposable assembly, so no separate reusable cartridge housing is required for the capsule itself. This simplifies filter replacement in laboratory, pilot and small-process filtration systems.
Nylon is naturally hydrophilic, allowing aqueous liquids to wet the membrane readily. The documented membrane also combines this hydrophilic behaviour with alcohol resistance, which makes Nylon particularly interesting for compatible aqueous and alcohol-containing process fluids.
The membrane is also documented as having low protein adsorption. However, membrane selection for valuable proteins or biological products should still be based on actual compatibility and recovery testing rather than membrane material alone.
Six selectable pore sizes allow the Nylon capsule to cover different fine filtration and clarification requirements.
Fine-pore configurations for applications requiring a high level of particulate retention. Where microbial or sterile performance is required, the exact filter grade and validation documentation must be confirmed.
Common fine-filtration ratings for clarification, laboratory filtration and compatible aqueous or alcohol-containing solutions.
Larger-pore configurations for particulate reduction and clarification where higher solids loading or lower flow resistance is required.
Available ratings are 0.1, 0.2, 0.45, 0.65, 1.0 and 3.0 µm. Selection should consider required retention, solids loading, liquid compatibility and allowable pressure drop.
Nylon membrane capsules are especially relevant when the process includes water-based liquids, alcohol-containing solutions or compatible solvent mixtures.
Typical use can include laboratory analysis, sample preparation, process development and fine filtration of compatible aqueous or alcohol-based process fluids.
Chemical compatibility: “alcohol resistant” should not be interpreted as universal compatibility with every organic solvent or chemical. Confirm membrane and housing compatibility against the actual liquid, concentration, temperature and exposure time.
The current Filtra Nylon capsule range includes multiple inlet and outlet options for integration into laboratory tubing, pilot equipment and process systems.
| NPT | 1/4" NPT male, 3/8" NPT male, 1/2" NPT male and 3/8" NPT female options |
|---|---|
| Swagelok | 1/4", 5/16", 3/8" and 1/2" selectable connection options |
| CPC quick-connect | 1/4" CPC PLC male and female configurations |
| Hose barb | 3/8", 1/2" and 1/4"–3/8" stepped hose-barb options |
| Sanitary connection | 1" Tri-Clamp / Tri-Clover |
Exact fitting availability can depend on capsule size and configuration. Confirm the inlet and outlet combination required for the installation.
Filtra's current selectable Nylon capsule configurations include 1.5", 2.5", 5", 10" and 20" lengths.
Larger capsule formats can provide increased filtration area and throughput, but the documented 300 cm² specification belongs to the compact capsule configuration and should not be applied automatically to every larger size.
| Nylon | PES | PVDF | |
|---|---|---|---|
| Wettability | Hydrophilic | Hydrophilic | Hydrophilic |
| Key selection feature | Alcohol resistance | Strong hydrophilicity and low protein adsorption | Low protein adsorption |
| Typical starting point | Aqueous and compatible alcohol-based liquids | Aqueous process liquids and buffers | Protein-sensitive and compatible process liquids |
| Final selection | Confirm chemical compatibility, retention requirement, product recovery and process conditions for the actual liquid. | ||
The documented compact Nylon capsule range includes several quality and material characteristics relevant to laboratory, biotechnology and process filtration.
These specifications apply to the documented capsule configuration. Requirements for regulated pharmaceutical processes should be confirmed against the exact membrane grade, size and supporting documentation.
Nylon capsules can be useful in pharmaceutical R&D, biotechnology laboratories and pilot-scale filtration where the process liquid is chemically compatible with the membrane.
For regulated sterile or bioburden-reduction processes, a nominal 0.2 µm Nylon membrane should not automatically be treated as sterilizing grade. The applicable retention validation, integrity-test limits and product documentation must be confirmed for the exact filter grade.
Correct selection should consider the complete liquid and process conditions.
Not sure whether Nylon, PES, PVDF or PTFE is the best membrane for your liquid? Send us the fluid composition, pore size, process volume and connection requirements for technical selection support.
A Nylon membrane capsule filter is a self-contained disposable filter containing a hydrophilic Nylon membrane inside a polymer capsule. It is used for fine filtration and clarification of compatible aqueous, alcohol-containing and process liquids.
Yes. The documented Nylon membrane is naturally hydrophilic and can therefore wet readily with compatible aqueous liquids without hydrophobic-membrane pre-wetting.
Yes. The documented Nylon membrane combines hydrophilicity with alcohol resistance and is suitable for compatible aqueous and alcohol-based liquids. Compatibility should still be checked for the specific alcohol concentration, temperature and process conditions.
Available Nylon capsule pore sizes include 0.1, 0.2, 0.45, 0.65, 1.0 and 3.0 µm.
Yes. A 0.2 µm Nylon configuration is available. A 0.2 µm pore size alone, however, should not be interpreted as proof of validated sterilizing-grade performance.
Filtra currently offers 1.5-inch, 2.5-inch, 5-inch, 10-inch and 20-inch selectable Nylon capsule configurations.
Current Filtra options include NPT, Swagelok, CPC quick-connect, hose-barb and 1-inch Tri-Clamp / Tri-Clover connections.
The documented compact Nylon capsule configuration provides approximately 300 cm² of filtration area. Larger capsule configurations can have different effective filtration areas.
The documented compact Nylon capsule configuration supports autoclaving at 121 °C for 30 minutes over multiple cycles. Confirm the limit for the exact capsule configuration selected.
The documented compact Nylon capsule range is 100% integrity tested during manufacturing. For regulated applications, confirm the test method and acceptance specification for the exact selected configuration.
Selecting the correct filtration solution often requires verification under real process conditions. Filtra International supports this process through several practical testing and validation options.
• Filter samples – available for compatibility and performance checks in existing filter housings.
• Full-scale filter housing rental – for temporary installations or process evaluation.
• Laboratory and pilot-scale filtration units – enabling controlled testing before full implementation.
• Application testing by our team – customers may send product samples for filtration trials and performance evaluation.
These options allow process validation before committing to a permanent installation.
Share a few details about your process and our team can assist with product selection and sizing.
Typical parameters include:
• Flow rate
• Particle size or filtration rating
• Temperature and pressure
• Chemical composition of the media