{"product_id":"non-invasive-bubble-detector-bioprocess-tubing","title":"Non-Invasive Bubble Detector for Bioprocess Tubing","description":"\u003ch2\u003eProduct description\u003c\/h2\u003e\n\n\u003cp\u003e\n  Non-invasive bubble detectors are designed to detect unwanted air or gas\n  bubbles in liquid-filled pharmaceutical, bioprocess and medical tubing.\n  Measurement takes place through the tubing wall, so the sensor does not come\n  into direct contact with the process medium.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The tubing is inserted directly into the detector, allowing continuous\n  monitoring of the fluid path without introducing an additional wetted\n  component. Depending on the configuration, the sensor can detect microbubbles,\n  larger gas inclusions, foam and whether the tubing is completely full or empty.\n\u003c\/p\u003e\n\n\n\u003ch3\u003eTechnical overview\u003c\/h3\u003e\n\n\u003cp\u003e\n  Bubble detection is particularly relevant in processes where uninterrupted\n  liquid flow must be verified and unwanted gas inclusions need to be detected\n  before they reach the next process step.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The non-invasive measuring principle keeps the sensor physically separated\n  from the product. This avoids adding another product-contact surface to the\n  fluid path and makes the detector particularly suitable for single-use tubing\n  systems and other hygienic process applications.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Clear flexible tubing materials such as silicone, TPE and PVC can be monitored.\n  Suitable reinforced transparent tubing can also be used. The detector is\n  intended primarily for water-like or low-viscosity liquids containing little\n  or no suspended solids.\n\u003c\/p\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eOperating principle\u003c\/h2\u003e\n\n\u003cp\u003e\n  The bubble detector measures through the wall of the tubing rather than\n  contacting the liquid directly. The filled tubing is positioned inside the\n  sensor, which continuously monitors the condition of the fluid path.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Liquid and gas have different transmission characteristics. When an air or gas\n  bubble passes through the sensing area, the detector identifies the change and\n  generates the configured output signal.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Depending on the sensor configuration and sensitivity setting, the same\n  principle can be used for microbubble detection, general bubble monitoring,\n  foam detection and full-or-empty detection of the tubing.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Because the tubing itself remains closed, the sensor can be installed without\n  creating an additional process connection, wetted fitting or penetration into\n  the fluid path.\n\u003c\/p\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eMaterial options\u003c\/h2\u003e\n\n\u003cp\u003e\n  The bubble detector itself does not form part of the wetted process path.\n  Material compatibility therefore primarily concerns the tubing being monitored.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Suitable transparent tubing materials include:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eSilicone tubing\u003c\/li\u003e\n  \u003cli\u003eTPE tubing\u003c\/li\u003e\n  \u003cli\u003ePVC tubing\u003c\/li\u003e\n  \u003cli\u003eSuitable transparent reinforced tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Tubing transparency, wall thickness, diameter, reinforcement and process-fluid\n  properties should be considered when selecting the appropriate sensor\n  configuration.\n\u003c\/p\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eAvailable micron ratings\u003c\/h2\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eNot applicable.\u003c\/strong\u003e A bubble detector is a process-monitoring\n  sensor rather than filtration media and therefore does not have a micron or\n  pore-size rating.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  The detector can, however, be configured for sensitive detection of small gas\n  inclusions or microbubbles. The required detection sensitivity should be\n  specified according to the application.\n\u003c\/p\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eDesign and construction\u003c\/h2\u003e\n\n\u003cp\u003e\n  Non-invasive bubble detectors are available in different sizes and electronic\n  configurations to suit different tubing dimensions and process requirements.\n  The tubing is inserted into the sensor without requiring a separate mounting\n  or product-contact fitting.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Depending on the selected configuration, technical features can include:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eNon-invasive measurement through the tubing wall\u003c\/li\u003e\n  \u003cli\u003eMicrobubble detection\u003c\/li\u003e\n  \u003cli\u003eFull \/ empty tubing detection\u003c\/li\u003e\n  \u003cli\u003eFoam detection\u003c\/li\u003e\n  \u003cli\u003eAdjustable sensor sensitivity\u003c\/li\u003e\n  \u003cli\u003eIntegrated electronics\u003c\/li\u003e\n  \u003cli\u003eAutomatic or cyclic self-test functions\u003c\/li\u003e\n  \u003cli\u003eConfigurable electronic outputs\u003c\/li\u003e\n  \u003cli\u003eModular sensor configurations\u003c\/li\u003e\n  \u003cli\u003eOptional configurations for hazardous areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003ch3\u003eElectrical and signal options\u003c\/h3\u003e\n\n\u003cp\u003e\n  The available sensor family supports several electronic interface options,\n  depending on the selected detector configuration.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Available signal and communication types can include:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eTTL logic\u003c\/li\u003e\n  \u003cli\u003eSerial communication\u003c\/li\u003e\n  \u003cli\u003ePWM output\u003c\/li\u003e\n  \u003cli\u003ePNP output\u003c\/li\u003e\n  \u003cli\u003e0–10 VDC analogue output\u003c\/li\u003e\n  \u003cli\u003e4–20 mA analogue output\u003c\/li\u003e\n  \u003cli\u003eRS485 communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  Available supply voltages depend on the sensor configuration and can include\n  5 VDC or a wider 12–30 VDC supply range.\n\u003c\/p\u003e\n\n\n\u003ch3\u003eCompliance and hazardous-area options\u003c\/h3\u003e\n\n\u003cp\u003e\n  Depending on the selected configuration, available conformity information\n  includes CE and RoHS \/ REACH documentation. Certain detector configurations\n  can also be supplied with an optional ATEX certificate for use in potentially\n  explosive environments.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Exact certifications, supply voltage and signal outputs should be confirmed\n  for the final sensor configuration.\n\u003c\/p\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\n\u003cp\u003e\n  Non-invasive bubble detectors are used in processes where gas inclusion,\n  interrupted liquid supply or empty tubing could affect process control,\n  filling accuracy or equipment operation.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003ePharmaceutical filling processes\u003c\/li\u003e\n  \u003cli\u003eFill \u0026amp; Finish\u003c\/li\u003e\n  \u003cli\u003eSterile filtration\u003c\/li\u003e\n  \u003cli\u003eGeneral filtration applications\u003c\/li\u003e\n  \u003cli\u003eBioreactor processes\u003c\/li\u003e\n  \u003cli\u003eFermentation\u003c\/li\u003e\n  \u003cli\u003eLiquid dosing systems\u003c\/li\u003e\n  \u003cli\u003eMixing systems\u003c\/li\u003e\n  \u003cli\u003ePipetting systems\u003c\/li\u003e\n  \u003cli\u003eSingle-use tubing assemblies\u003c\/li\u003e\n  \u003cli\u003eFluid transfer systems\u003c\/li\u003e\n  \u003cli\u003eMedical pumps\u003c\/li\u003e\n  \u003cli\u003eDiagnostic systems\u003c\/li\u003e\n  \u003cli\u003eDialysis systems\u003c\/li\u003e\n  \u003cli\u003eBlood handling and separation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003eNon-invasive measurement:\u003c\/strong\u003e\n    the sensor monitors through the tubing wall without direct product contact.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eClosed fluid path:\u003c\/strong\u003e\n    no additional wetted sensor body or process penetration is required.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMicrobubble detection:\u003c\/strong\u003e\n    suitable configurations can detect small gas inclusions in the liquid stream.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMultiple detection functions:\u003c\/strong\u003e\n    the sensor can also be used for foam monitoring and full-or-empty detection.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSimple tubing installation:\u003c\/strong\u003e\n    flexible tubing can be inserted into the sensing area without additional\n    product-contact fittings.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eAdjustable sensitivity:\u003c\/strong\u003e\n    sensor response can be adapted according to the application.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eMultiple electronic interfaces:\u003c\/strong\u003e\n    digital, serial and analogue output options are available depending on the\n    configuration.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSuitable for single-use systems:\u003c\/strong\u003e\n    the non-contact measuring principle allows the disposable tubing to remain\n    the complete product-contact surface.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003chr\u003e\n\n\n\u003ch2\u003eConfiguration and quotation\u003c\/h2\u003e\n\n\u003cp\u003e\n  The correct bubble detector should be selected according to the tubing,\n  process liquid, required detection sensitivity and control-system interface.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  For technical selection and quotation, provide the following information\n  where available:\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eTubing material\u003c\/li\u003e\n  \u003cli\u003eTubing inner diameter\u003c\/li\u003e\n  \u003cli\u003eTubing outer diameter\u003c\/li\u003e\n  \u003cli\u003eTubing wall thickness\u003c\/li\u003e\n  \u003cli\u003eWhether the tubing is reinforced\u003c\/li\u003e\n  \u003cli\u003eProcess liquid\u003c\/li\u003e\n  \u003cli\u003eLiquid viscosity\u003c\/li\u003e\n  \u003cli\u003ePresence of solids or suspended particles\u003c\/li\u003e\n  \u003cli\u003eRequired bubble detection sensitivity\u003c\/li\u003e\n  \u003cli\u003eMicrobubble detection requirement\u003c\/li\u003e\n  \u003cli\u003eFull \/ empty detection requirement\u003c\/li\u003e\n  \u003cli\u003eFoam detection requirement\u003c\/li\u003e\n  \u003cli\u003eRequired supply voltage\u003c\/li\u003e\n  \u003cli\u003eRequired electrical output or communication interface\u003c\/li\u003e\n  \u003cli\u003eATEX requirement, where applicable\u003c\/li\u003e\n  \u003cli\u003eRequired quantity\u003c\/li\u003e\n  \u003cli\u003eWhether the detector will be integrated with a single-use assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  If the exact sensor configuration is not yet known, tubing dimensions and a\n  description of the process are usually sufficient as a starting point for\n  selection.\n\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is a non-invasive bubble detector?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A non-invasive bubble detector is a sensor that monitors liquid-filled tubing for air or gas bubbles without contacting the process medium. Measurement takes place through the tubing wall.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a bubble detector detect microbubbles?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Suitable sensor configurations can detect small gas inclusions or microbubbles, with sensitivity adjusted according to the application.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What tubing materials can be used with a bubble detector?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Suitable clear tubing materials include silicone, TPE and PVC. Transparent reinforced tubing can also be monitored with suitable sensor configurations.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a bubble sensor detect whether tubing is full or empty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. In addition to bubble detection, the sensor can be used as a full-or-empty detector for liquid tubing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Where are non-invasive bubble detectors used?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Typical applications include pharmaceutical filling, sterile filtration, bioreactors, fermentation, dosing, mixing, fluid transfer, diagnostics and medical pumping systems.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can bubble detectors be used in ATEX areas?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Certain bubble detector configurations are available with optional ATEX certification for use in potentially explosive environments.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Filtra International","offers":[{"title":"Bubble Detection \/ TTL Logic \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216578886,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ TTL Logic \/ OD \u0026 Wall Thickness","offer_id":57319216611654,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ Serial \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216644422,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ Serial \/ OD \u0026 Wall Thickness","offer_id":57319216677190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ PWM \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216709958,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ PWM \/ OD \u0026 Wall Thickness","offer_id":57319216742726,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ PNP \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216775494,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ PNP \/ OD \u0026 Wall Thickness","offer_id":57319216808262,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ 0–10 VDC \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216841030,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ 0–10 VDC \/ OD \u0026 Wall Thickness","offer_id":57319216873798,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ 4–20 mA \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216906566,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ 4–20 mA \/ OD \u0026 Wall Thickness","offer_id":57319216939334,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ RS485 \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319216972102,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ RS485 \/ OD \u0026 Wall Thickness","offer_id":57319217004870,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ To Be Specified \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217037638,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble Detection \/ To Be Specified \/ OD \u0026 Wall Thickness","offer_id":57319217070406,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ TTL Logic \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217103174,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ TTL Logic \/ OD \u0026 Wall Thickness","offer_id":57319217135942,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ Serial \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217168710,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ Serial \/ OD \u0026 Wall Thickness","offer_id":57319217201478,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ PWM \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217234246,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ PWM \/ OD \u0026 Wall Thickness","offer_id":57319217267014,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ PNP \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217299782,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ PNP \/ OD \u0026 Wall Thickness","offer_id":57319217332550,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ 0–10 VDC \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217365318,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ 0–10 VDC \/ OD \u0026 Wall Thickness","offer_id":57319217398086,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ 4–20 mA \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217430854,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ 4–20 mA \/ OD \u0026 Wall Thickness","offer_id":57319217463622,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ RS485 \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217496390,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ RS485 \/ OD \u0026 Wall Thickness","offer_id":57319217529158,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ To Be Specified \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217561926,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Microbubble Detection \/ To Be Specified \/ OD \u0026 Wall Thickness","offer_id":57319217594694,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ TTL Logic \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217627462,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ TTL Logic \/ OD \u0026 Wall Thickness","offer_id":57319217660230,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ Serial \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217692998,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ Serial \/ OD \u0026 Wall Thickness","offer_id":57319217725766,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ PWM \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217758534,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ PWM \/ OD \u0026 Wall Thickness","offer_id":57319217791302,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ PNP \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217824070,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ PNP \/ OD \u0026 Wall Thickness","offer_id":57319217856838,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ 0–10 VDC \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217889606,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ 0–10 VDC \/ OD \u0026 Wall Thickness","offer_id":57319217922374,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ 4–20 mA \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319217955142,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ 4–20 mA \/ OD \u0026 Wall Thickness","offer_id":57319217987910,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ RS485 \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218020678,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ RS485 \/ OD \u0026 Wall Thickness","offer_id":57319218053446,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ To Be Specified \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218086214,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Full\/Empty Detection \/ To Be Specified \/ OD \u0026 Wall Thickness","offer_id":57319218118982,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ TTL Logic \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218151750,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ TTL Logic \/ OD \u0026 Wall Thickness","offer_id":57319218184518,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ Serial \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218217286,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ Serial \/ OD \u0026 Wall Thickness","offer_id":57319218250054,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ PWM \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218282822,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ PWM \/ OD \u0026 Wall Thickness","offer_id":57319218315590,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ PNP \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218348358,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ PNP \/ OD \u0026 Wall Thickness","offer_id":57319218381126,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ 0–10 VDC \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218413894,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ 0–10 VDC \/ OD \u0026 Wall Thickness","offer_id":57319218446662,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ 4–20 mA \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218479430,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ 4–20 mA \/ OD \u0026 Wall Thickness","offer_id":57319218512198,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ RS485 \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218544966,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ RS485 \/ OD \u0026 Wall Thickness","offer_id":57319218577734,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ To Be Specified \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218610502,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Bubble + Foam Detection \/ To Be Specified \/ OD \u0026 Wall Thickness","offer_id":57319218643270,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ TTL Logic \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218676038,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ TTL Logic \/ OD \u0026 Wall Thickness","offer_id":57319218708806,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ Serial \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218741574,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ Serial \/ OD \u0026 Wall Thickness","offer_id":57319218774342,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ PWM \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218807110,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ PWM \/ OD \u0026 Wall Thickness","offer_id":57319218839878,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ PNP \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218872646,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ PNP \/ OD \u0026 Wall Thickness","offer_id":57319218905414,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ 0–10 VDC \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319218938182,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ 0–10 VDC \/ OD \u0026 Wall Thickness","offer_id":57319218970950,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ 4–20 mA \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319219003718,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ 4–20 mA \/ OD \u0026 Wall Thickness","offer_id":57319219036486,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ RS485 \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319219069254,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ RS485 \/ OD \u0026 Wall Thickness","offer_id":57319219102022,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ To Be Specified \/ Custom – Please Specify Tubing ID\/ OD \u0026 Wall Thickness","offer_id":57319219134790,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Custom \/ To Be Specified \/ To Be Specified \/ OD \u0026 Wall Thickness","offer_id":57319219167558,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/2985\/6326\/files\/non-invasive-bubble-detector-bioprocess-tubing.webp?v=1788967499","url":"https:\/\/filtrainternational.com\/products\/non-invasive-bubble-detector-bioprocess-tubing","provider":"Filtra International","version":"1.0","type":"link"}