{"title":"Heavy duty filter housing","description":"","products":[{"product_id":"filter-housing-to-asme-u","title":"Filter Housing Manufactured to ASME U","description":"\u003ch2 data-start=\"283\" data-end=\"307\"\u003eProduct description\u003c\/h2\u003e\n\u003ch3 data-start=\"309\" data-end=\"397\"\u003eFilter housing manufactured according to ASME Section VIII Division 1 with U Stamp\u003c\/h3\u003e\n\u003cp data-start=\"399\" data-end=\"666\"\u003eThis filter housing is manufactured in accordance with ASME Section VIII Division 1 and supplied with ASME U stamp certification. It is designed for industrial filtration applications where compliance with American and international pressure vessel codes is required.\u003c\/p\u003e\n\u003cp data-start=\"668\" data-end=\"959\"\u003eASME U certification confirms that the filter housing is designed, fabricated, inspected and tested according to the ASME Boiler and Pressure Vessel Code. This makes the housing suitable for installations in the United States and in international projects where ASME compliance is specified.\u003c\/p\u003e\n\u003cp data-start=\"961\" data-end=\"1144\"\u003eThese filter housings are typically used in high pressure and safety critical applications where documented design calculations, traceability and third party inspection are mandatory.\u003c\/p\u003e\n\u003chr data-start=\"1146\" data-end=\"1149\"\u003e\n\u003ch3 data-start=\"1151\" data-end=\"1177\"\u003eASME U certification\u003c\/h3\u003e\n\u003cp data-start=\"1179\" data-end=\"1280\"\u003eASME U stamp certification covers the complete lifecycle of pressure vessel manufacturing, including:\u003c\/p\u003e\n\u003cul data-start=\"1281\" data-end=\"1528\"\u003e\n\u003cli data-start=\"1281\" data-end=\"1328\"\u003e\n\u003cp data-start=\"1283\" data-end=\"1328\"\u003edesign calculations according to ASME rules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1329\" data-end=\"1367\"\u003e\n\u003cp data-start=\"1331\" data-end=\"1367\"\u003eapproved pressure vessel materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1414\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1414\"\u003equalified welding procedures and personnel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1415\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1417\" data-end=\"1454\"\u003einspection by authorized inspectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1487\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1487\"\u003ehydrostatic pressure testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1488\" data-end=\"1528\"\u003e\n\u003cp data-start=\"1490\" data-end=\"1528\"\u003ecomplete manufacturing documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1530\" data-end=\"1635\"\u003eOnly manufacturers holding valid ASME authorization are allowed to apply the U stamp to pressure vessels.\u003c\/p\u003e\n\u003chr data-start=\"1637\" data-end=\"1640\"\u003e\n\u003ch3 data-start=\"1642\" data-end=\"1672\"\u003eDesign and configuration\u003c\/h3\u003e\n\u003cp data-start=\"1674\" data-end=\"1910\"\u003eThe filter housing is engineered as a pressure rated vessel and designed to meet specified operating pressure and temperature limits. Each housing is custom designed to suit the required filtration principle and installation conditions.\u003c\/p\u003e\n\u003cp data-start=\"1912\" data-end=\"1950\"\u003eTypical configuration options include:\u003c\/p\u003e\n\u003cul data-start=\"1951\" data-end=\"2134\"\u003e\n\u003cli data-start=\"1951\" data-end=\"1981\"\u003e\n\u003cp data-start=\"1953\" data-end=\"1981\"\u003evessel diameter and length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2030\"\u003e\n\u003cp data-start=\"1984\" data-end=\"2030\"\u003einlet and outlet nozzle size and orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2049\"\u003e\n\u003cp data-start=\"2033\" data-end=\"2049\"\u003eclosure system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2050\" data-end=\"2091\"\u003e\n\u003cp data-start=\"2052\" data-end=\"2091\"\u003einternal filter element configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2134\"\u003e\n\u003cp data-start=\"2094\" data-end=\"2134\"\u003esurface finish and corrosion allowance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2136\" data-end=\"2234\"\u003eThe housing can be supplied as a stand alone unit or integrated into a complete filtration system.\u003c\/p\u003e\n\u003chr data-start=\"2236\" data-end=\"2239\"\u003e\n\u003ch3 data-start=\"2241\" data-end=\"2272\"\u003eMaterials of construction\u003c\/h3\u003e\n\u003cp data-start=\"2274\" data-end=\"2510\"\u003eFilter housings manufactured to ASME U are produced using ASME approved carbon steel or stainless steel materials. Material selection is based on pressure rating, operating temperature and chemical compatibility with the process medium.\u003c\/p\u003e\n\u003cp data-start=\"2512\" data-end=\"2592\"\u003eAll materials are fully traceable and documented according to ASME requirements.\u003c\/p\u003e\n\u003chr data-start=\"2594\" data-end=\"2597\"\u003e\n\u003ch3 data-start=\"2599\" data-end=\"2617\"\u003eKey benefits\u003c\/h3\u003e\n\u003cul data-start=\"2619\" data-end=\"2889\"\u003e\n\u003cli data-start=\"2619\" data-end=\"2677\"\u003e\n\u003cp data-start=\"2621\" data-end=\"2677\"\u003eManufactured according to ASME Section VIII Division 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2678\" data-end=\"2722\"\u003e\n\u003cp data-start=\"2680\" data-end=\"2722\"\u003eSupplied with ASME U stamp certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2723\" data-end=\"2766\"\u003e\n\u003cp data-start=\"2725\" data-end=\"2766\"\u003eSuitable for high pressure applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2767\" data-end=\"2811\"\u003e\n\u003cp data-start=\"2769\" data-end=\"2811\"\u003eThird party inspection and documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2812\" data-end=\"2842\"\u003e\n\u003cp data-start=\"2814\" data-end=\"2842\"\u003eCustom engineered to order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2889\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2889\"\u003eAccepted for US and international projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2891\" data-end=\"2894\"\u003e\n\u003ch3 data-start=\"2896\" data-end=\"2922\"\u003eTypical applications\u003c\/h3\u003e\n\u003cp data-start=\"2924\" data-end=\"2978\"\u003eASME U certified filter housings are commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"2979\" data-end=\"3141\"\u003e\n\u003cli data-start=\"2979\" data-end=\"3020\"\u003e\n\u003cp data-start=\"2981\" data-end=\"3020\"\u003echemical and petrochemical industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3021\" data-end=\"3047\"\u003e\n\u003cp data-start=\"3023\" data-end=\"3047\"\u003eoil and gas processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3048\" data-end=\"3068\"\u003e\n\u003cp data-start=\"3050\" data-end=\"3068\"\u003epower generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3069\" data-end=\"3102\"\u003e\n\u003cp data-start=\"3071\" data-end=\"3102\"\u003eindustrial process filtration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3103\" data-end=\"3141\"\u003e\n\u003cp data-start=\"3105\" data-end=\"3141\"\u003einternational engineering projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3143\" data-end=\"3146\"\u003e\n\u003ch3 data-start=\"3148\" data-end=\"3179\"\u003eVariants and filter types\u003c\/h3\u003e\n\u003cp data-start=\"3181\" data-end=\"3286\"\u003eThis product page represents a generic ASME U certified filter housing. The housing can be configured as:\u003c\/p\u003e\n\u003cul data-start=\"3287\" data-end=\"3434\"\u003e\n\u003cli data-start=\"3287\" data-end=\"3309\"\u003e\n\u003cp data-start=\"3289\" data-end=\"3309\"\u003ebag filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3310\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3312\" data-end=\"3335\"\u003ebasket filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3361\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3361\"\u003ecandle filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3362\" data-end=\"3388\"\u003e\n\u003cp data-start=\"3364\" data-end=\"3388\"\u003emodular filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3389\" data-end=\"3434\"\u003e\n\u003cp data-start=\"3391\" data-end=\"3434\"\u003efilter housing with quick release closure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3436\" data-end=\"3439\"\u003e\n\u003ch3 data-start=\"3441\" data-end=\"3474\"\u003eConfiguration and quotation\u003c\/h3\u003e\n\u003cp data-start=\"3476\" data-end=\"3579\"\u003eFilter housings manufactured to ASME U are supplied on a quotation basis. This allows configuration of:\u003c\/p\u003e\n\u003cul data-start=\"3580\" data-end=\"3742\"\u003e\n\u003cli data-start=\"3580\" data-end=\"3603\"\u003e\n\u003cp data-start=\"3582\" data-end=\"3603\"\u003efilter housing type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3604\" data-end=\"3639\"\u003e\n\u003cp data-start=\"3606\" data-end=\"3639\"\u003edesign pressure and temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3640\" data-end=\"3677\"\u003e\n\u003cp data-start=\"3642\" data-end=\"3677\"\u003evessel dimensions and connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3678\" data-end=\"3696\"\u003e\n\u003cp data-start=\"3680\" data-end=\"3696\"\u003ematerial grade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3697\" data-end=\"3742\"\u003e\n\u003cp data-start=\"3699\" data-end=\"3742\"\u003einspection and documentation requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3744\" data-end=\"3833\"\u003eThis ensures the filter housing fully complies with ASME code and project specifications.\u003c\/p\u003e\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does ASME U mean for a filter housing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"ASME U indicates that the filter housing is manufactured according to ASME Section VIII Division 1 and is certified as a pressure vessel with an official U stamp.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is an ASME U filter housing suitable for use in the United States?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. ASME U certified filter housings are accepted for use in the United States and in international projects that specify ASME compliance.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which filter types can be manufactured with ASME U certification?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"ASME U certified filter housings can be supplied as bag filters, basket filters, candle filters, modular housings or housings with quick release closure.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Are ASME U filter housings pressure tested?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. All ASME U certified filter housings undergo hydrostatic pressure testing as part of the certification process.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can ASME U filter housings be custom engineered?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. These filter housings are custom engineered to meet specific pressure, temperature, material and process requirements.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Filtra International","offers":[{"title":"Bag filter housing","offer_id":55771797487942,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Basket filter housing","offer_id":55771797520710,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Candle filter housing","offer_id":55771797553478,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Modular filter housing","offer_id":55771797586246,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Filter housing with quick release closure","offer_id":55771797619014,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/2985\/6326\/files\/FilterHousingtoASMEU.png?v=1766098239"},{"product_id":"filter-housing-to-ped-module-a2-module-g","title":"Filter Housing Manufactured to PED Module A2 and Module G","description":"\u003ch2 data-start=\"274\" data-end=\"298\"\u003eProduct description\u003c\/h2\u003e\n\u003ch3 data-start=\"300\" data-end=\"373\"\u003eFilter housing manufactured according to PED Module A2 and Module G\u003c\/h3\u003e\n\u003cp data-start=\"375\" data-end=\"652\"\u003eThis filter housing is manufactured in accordance with the Pressure Equipment Directive PED 2014\/68\/EU using Module A2 or Module G conformity assessment routes. It is designed for industrial filtration applications where formal European pressure equipment approval is required.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"1043\"\u003eCompliance with PED ensures that the filter housing meets essential safety requirements for pressure equipment placed on the European market. Depending on the application and pressure category, the housing is assessed either through Module A2, which includes production quality assurance with notified body surveillance, or through Module G, which involves individual product verification.\u003c\/p\u003e\n\u003cp data-start=\"1045\" data-end=\"1180\"\u003eThese filter housings are suitable for installations where regulatory compliance, traceability and documented conformity are mandatory.\u003c\/p\u003e\n\u003chr data-start=\"1182\" data-end=\"1185\"\u003e\n\u003ch3 data-start=\"1187\" data-end=\"1230\"\u003ePED conformity and assessment modules\u003c\/h3\u003e\n\u003cp data-start=\"1232\" data-end=\"1356\"\u003eThe Pressure Equipment Directive defines different conformity assessment modules based on pressure category and application.\u003c\/p\u003e\n\u003cp data-start=\"1358\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1358\" data-end=\"1375\"\u003ePED Module A2\u003c\/strong\u003e\u003cbr data-start=\"1375\" data-end=\"1378\"\u003eModule A2 is based on internal production control with supervised pressure equipment checks. It includes manufacturing controls and notified body involvement for final inspection and testing.\u003c\/p\u003e\n\u003cp data-start=\"1571\" data-end=\"1767\"\u003e\u003cstrong data-start=\"1571\" data-end=\"1587\"\u003ePED Module G\u003c\/strong\u003e\u003cbr data-start=\"1587\" data-end=\"1590\"\u003eModule G applies to individually assessed pressure equipment. Each filter housing is fully verified by a notified body, including design review, inspection and pressure testing.\u003c\/p\u003e\n\u003cp data-start=\"1769\" data-end=\"1910\"\u003eBoth modules ensure that the filter housing complies with PED requirements and can be supplied with CE marking and declaration of conformity.\u003c\/p\u003e\n\u003chr data-start=\"1912\" data-end=\"1915\"\u003e\n\u003ch3 data-start=\"1917\" data-end=\"1947\"\u003eDesign and configuration\u003c\/h3\u003e\n\u003cp data-start=\"1949\" data-end=\"2176\"\u003eThe filter housing is engineered as a pressure rated vessel and designed according to defined operating pressure and temperature limits. Each design is adapted to the specific filtration principle and installation requirements.\u003c\/p\u003e\n\u003cp data-start=\"2178\" data-end=\"2220\"\u003eConfigurable parameters typically include:\u003c\/p\u003e\n\u003cul data-start=\"2221\" data-end=\"2382\"\u003e\n\u003cli data-start=\"2221\" data-end=\"2252\"\u003e\n\u003cp data-start=\"2223\" data-end=\"2252\"\u003evessel size and orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2253\" data-end=\"2285\"\u003e\n\u003cp data-start=\"2255\" data-end=\"2285\"\u003einlet and outlet connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2286\" data-end=\"2304\"\u003e\n\u003cp data-start=\"2288\" data-end=\"2304\"\u003eclosure system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2305\" data-end=\"2339\"\u003e\n\u003cp data-start=\"2307\" data-end=\"2339\"\u003einternal filter element design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2340\" data-end=\"2382\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2382\"\u003esurface finish and corrosion allowance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2384\" data-end=\"2477\"\u003eThe housing can be supplied as a single unit or integrated into a complete filtration system.\u003c\/p\u003e\n\u003chr data-start=\"2479\" data-end=\"2482\"\u003e\n\u003ch3 data-start=\"2484\" data-end=\"2515\"\u003eMaterials of construction\u003c\/h3\u003e\n\u003cp data-start=\"2517\" data-end=\"2780\"\u003eFilter housings manufactured under PED Module A2 or Module G are produced using pressure approved materials such as stainless steel or carbon steel. Material selection is based on pressure category, operating temperature and compatibility with the process medium.\u003c\/p\u003e\n\u003cp data-start=\"2782\" data-end=\"2861\"\u003eAll materials are documented and traceable in accordance with PED requirements.\u003c\/p\u003e\n\u003chr data-start=\"2863\" data-end=\"2866\"\u003e\n\u003ch3 data-start=\"2868\" data-end=\"2886\"\u003eKey benefits\u003c\/h3\u003e\n\u003cul data-start=\"2888\" data-end=\"3159\"\u003e\n\u003cli data-start=\"2888\" data-end=\"2932\"\u003e\n\u003cp data-start=\"2890\" data-end=\"2932\"\u003eManufactured according to PED 2014\/68\/EU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2933\" data-end=\"2995\"\u003e\n\u003cp data-start=\"2935\" data-end=\"2995\"\u003eAvailable with Module A2 or Module G conformity assessment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2996\" data-end=\"3028\"\u003e\n\u003cp data-start=\"2998\" data-end=\"3028\"\u003eCE marked pressure equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3029\" data-end=\"3076\"\u003e\n\u003cp data-start=\"3031\" data-end=\"3076\"\u003eNotified body involvement and documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3077\" data-end=\"3128\"\u003e\n\u003cp data-start=\"3079\" data-end=\"3128\"\u003eSuitable for regulated industrial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3129\" data-end=\"3159\"\u003e\n\u003cp data-start=\"3131\" data-end=\"3159\"\u003eCustom engineered to order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3161\" data-end=\"3164\"\u003e\n\u003ch3 data-start=\"3166\" data-end=\"3192\"\u003eTypical applications\u003c\/h3\u003e\n\u003cp data-start=\"3194\" data-end=\"3245\"\u003ePED compliant filter housings are commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3246\" data-end=\"3439\"\u003e\n\u003cli data-start=\"3246\" data-end=\"3288\"\u003e\n\u003cp data-start=\"3248\" data-end=\"3288\"\u003echemical and pharmaceutical industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3336\"\u003e\n\u003cp data-start=\"3291\" data-end=\"3336\"\u003eindustrial liquid filtration under pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3337\" data-end=\"3370\"\u003e\n\u003cp data-start=\"3339\" data-end=\"3370\"\u003eprocess and plant engineering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3371\" data-end=\"3401\"\u003e\n\u003cp data-start=\"3373\" data-end=\"3401\"\u003eenergy and utility systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3402\" data-end=\"3439\"\u003e\n\u003cp data-start=\"3404\" data-end=\"3439\"\u003eregulated production environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3441\" data-end=\"3444\"\u003e\n\u003ch3 data-start=\"3446\" data-end=\"3477\"\u003eVariants and filter types\u003c\/h3\u003e\n\u003cp data-start=\"3479\" data-end=\"3581\"\u003eThis product page represents a generic PED compliant filter housing. The housing can be configured as:\u003c\/p\u003e\n\u003cul data-start=\"3582\" data-end=\"3729\"\u003e\n\u003cli data-start=\"3582\" data-end=\"3604\"\u003e\n\u003cp data-start=\"3584\" data-end=\"3604\"\u003ebag filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3605\" data-end=\"3630\"\u003e\n\u003cp data-start=\"3607\" data-end=\"3630\"\u003ebasket filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3631\" data-end=\"3656\"\u003e\n\u003cp data-start=\"3633\" data-end=\"3656\"\u003ecandle filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3657\" data-end=\"3683\"\u003e\n\u003cp data-start=\"3659\" data-end=\"3683\"\u003emodular filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3684\" data-end=\"3729\"\u003e\n\u003cp data-start=\"3686\" data-end=\"3729\"\u003efilter housing with quick release closure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3731\" data-end=\"3734\"\u003e\n\u003ch3 data-start=\"3736\" data-end=\"3769\"\u003eConfiguration and quotation\u003c\/h3\u003e\n\u003cp data-start=\"3771\" data-end=\"3893\"\u003eFilter housings manufactured to PED Module A2 or Module G are supplied on a quotation basis. This allows configuration of:\u003c\/p\u003e\n\u003cul data-start=\"3894\" data-end=\"4050\"\u003e\n\u003cli data-start=\"3894\" data-end=\"3917\"\u003e\n\u003cp data-start=\"3896\" data-end=\"3917\"\u003efilter housing type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3918\" data-end=\"3961\"\u003e\n\u003cp data-start=\"3920\" data-end=\"3961\"\u003epressure category and assessment module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3962\" data-end=\"3992\"\u003e\n\u003cp data-start=\"3964\" data-end=\"3992\"\u003edimensions and connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3993\" data-end=\"4011\"\u003e\n\u003cp data-start=\"3995\" data-end=\"4011\"\u003ematerial grade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4012\" data-end=\"4050\"\u003e\n\u003cp data-start=\"4014\" data-end=\"4050\"\u003edocumentation and inspection level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4052\" data-end=\"4124\"\u003eThis ensures full compliance with regulatory and technical requirements.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is PED Module A2 for filter housings?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"PED Module A2 is a conformity assessment route based on internal production control with supervised final inspection. It includes notified body involvement for pressure equipment verification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When is PED Module G used for filter housings?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"PED Module G is used for individually assessed pressure equipment. Each filter housing is verified by a notified body including design review, inspection and pressure testing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Are PED Module A2 and Module G filter housings CE marked?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Filter housings manufactured under PED Module A2 or Module G are supplied with CE marking and a declaration of conformity.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which filter types can be supplied under PED conformity?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"PED compliant filter housings can be configured as bag filters, basket filters, candle filters, modular housings or housings with quick release closure.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can PED compliant filter housings be custom manufactured?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. These filter housings are engineered to order, allowing customization of pressure rating, materials, size, connections and documentation level.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Filtra International","offers":[{"title":"Bag filter housing","offer_id":55771782611270,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Basket filter housing","offer_id":55771782644038,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Candle filter housing","offer_id":55771782676806,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Modular filter housing","offer_id":55771782709574,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Filter housing with quick release closure","offer_id":55771782742342,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/2985\/6326\/files\/FilterHousingtoPEDModuleA2_ModuleG.png?v=1766098432"},{"product_id":"filter-housing-to-ad-2000-hp0","title":"Filter Housing Manufactured to AD 2000 HP0","description":"\u003ch2 data-start=\"415\" data-end=\"439\"\u003eProduct description\u003c\/h2\u003e\n\u003ch3 data-start=\"441\" data-end=\"521\"\u003eFilter housing manufactured according to AD 2000 HP0 pressure vessel rules\u003c\/h3\u003e\n\u003cp data-start=\"523\" data-end=\"722\"\u003eThis filter housing is manufactured according to the AD 2000 HP0 code and is intended for industrial filtration applications where compliance with recognized German pressure vessel rules is required.\u003c\/p\u003e\n\u003cp data-start=\"724\" data-end=\"1056\"\u003eThe AD 2000 code is a widely accepted set of technical rules for the design, calculation, manufacture and testing of pressure equipment. Compliance with AD 2000 HP0 ensures that the filter housing meets defined safety and quality requirements for operation under pressure within the scope of European pressure equipment regulations.\u003c\/p\u003e\n\u003cp data-start=\"1058\" data-end=\"1235\"\u003eThese filter housings are typically used in demanding industrial environments where pressure resistance, material integrity and documented manufacturing processes are essential.\u003c\/p\u003e\n\u003chr data-start=\"1237\" data-end=\"1240\"\u003e\n\u003ch3 data-start=\"1242\" data-end=\"1270\"\u003eAD 2000 HP0 compliance\u003c\/h3\u003e\n\u003cp data-start=\"1272\" data-end=\"1354\"\u003eAD 2000 HP0 focuses on pressure bearing components and covers key aspects such as:\u003c\/p\u003e\n\u003cul data-start=\"1355\" data-end=\"1578\"\u003e\n\u003cli data-start=\"1355\" data-end=\"1396\"\u003e\n\u003cp data-start=\"1357\" data-end=\"1396\"\u003edesign and wall thickness calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1442\"\u003eapproved materials for pressure equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1490\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1490\"\u003ewelding procedures and welder qualification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1491\" data-end=\"1533\"\u003e\n\u003cp data-start=\"1493\" data-end=\"1533\"\u003enon destructive testing and inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1534\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1536\" data-end=\"1578\"\u003efinal pressure testing and documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1580\" data-end=\"1717\"\u003eManufacturing to AD 2000 HP0 provides a high level of confidence in the mechanical strength and operational safety of the filter housing.\u003c\/p\u003e\n\u003chr data-start=\"1719\" data-end=\"1722\"\u003e\n\u003ch3 data-start=\"1724\" data-end=\"1754\"\u003eDesign and configuration\u003c\/h3\u003e\n\u003cp data-start=\"1756\" data-end=\"1995\"\u003eThe filter housing is designed as a pressure rated vessel and can be configured for various filtration principles and installation requirements. The design is adapted to the specified operating pressure, temperature and process conditions.\u003c\/p\u003e\n\u003cp data-start=\"1997\" data-end=\"2039\"\u003eConfigurable parameters typically include:\u003c\/p\u003e\n\u003cul data-start=\"2040\" data-end=\"2208\"\u003e\n\u003cli data-start=\"2040\" data-end=\"2078\"\u003e\n\u003cp data-start=\"2042\" data-end=\"2078\"\u003enominal diameter and vessel length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2079\" data-end=\"2111\"\u003e\n\u003cp data-start=\"2081\" data-end=\"2111\"\u003einlet and outlet connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2112\" data-end=\"2130\"\u003e\n\u003cp data-start=\"2114\" data-end=\"2130\"\u003eclosure system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2131\" data-end=\"2165\"\u003e\n\u003cp data-start=\"2133\" data-end=\"2165\"\u003einternal filter element design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2166\" data-end=\"2208\"\u003e\n\u003cp data-start=\"2168\" data-end=\"2208\"\u003esurface finish and corrosion allowance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2210\" data-end=\"2308\"\u003eThe housing can be supplied as a stand alone unit or integrated into a complete filtration system.\u003c\/p\u003e\n\u003chr data-start=\"2310\" data-end=\"2313\"\u003e\n\u003ch3 data-start=\"2315\" data-end=\"2346\"\u003eMaterials of construction\u003c\/h3\u003e\n\u003cp data-start=\"2348\" data-end=\"2590\"\u003eFilter housings manufactured to AD 2000 HP0 are typically produced in pressure approved carbon steel or stainless steel grades. Material selection is based on operating pressure, temperature and chemical compatibility with the process medium.\u003c\/p\u003e\n\u003cp data-start=\"2592\" data-end=\"2684\"\u003eAll materials are selected and documented according to the requirements of the AD 2000 code.\u003c\/p\u003e\n\u003chr data-start=\"2686\" data-end=\"2689\"\u003e\n\u003ch3 data-start=\"2691\" data-end=\"2709\"\u003eKey benefits\u003c\/h3\u003e\n\u003cul data-start=\"2711\" data-end=\"3012\"\u003e\n\u003cli data-start=\"2711\" data-end=\"2774\"\u003e\n\u003cp data-start=\"2713\" data-end=\"2774\"\u003eManufactured according to AD 2000 HP0 pressure vessel rules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2775\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2777\" data-end=\"2830\"\u003eSuitable for pressure rated filtration applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2831\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2833\" data-end=\"2878\"\u003eDocumented design and manufacturing process\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2879\" data-end=\"2930\"\u003e\n\u003cp data-start=\"2881\" data-end=\"2930\"\u003eHigh mechanical strength and operational safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2931\" data-end=\"2961\"\u003e\n\u003cp data-start=\"2933\" data-end=\"2961\"\u003eCustom engineered to order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2962\" data-end=\"3012\"\u003e\n\u003cp data-start=\"2964\" data-end=\"3012\"\u003eSuitable for demanding industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3014\" data-end=\"3017\"\u003e\n\u003ch3 data-start=\"3019\" data-end=\"3045\"\u003eTypical applications\u003c\/h3\u003e\n\u003cp data-start=\"3047\" data-end=\"3096\"\u003eAD 2000 HP0 filter housings are commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3097\" data-end=\"3293\"\u003e\n\u003cli data-start=\"3097\" data-end=\"3132\"\u003e\n\u003cp data-start=\"3099\" data-end=\"3132\"\u003echemical and process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3133\" data-end=\"3180\"\u003e\n\u003cp data-start=\"3135\" data-end=\"3180\"\u003eindustrial liquid filtration under pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3181\" data-end=\"3216\"\u003e\n\u003cp data-start=\"3183\" data-end=\"3216\"\u003eutilities and plant engineering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3217\" data-end=\"3255\"\u003e\n\u003cp data-start=\"3219\" data-end=\"3255\"\u003eoil, fuel and lubricant filtration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3256\" data-end=\"3293\"\u003e\n\u003cp data-start=\"3258\" data-end=\"3293\"\u003eprocess water and cooling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3295\" data-end=\"3298\"\u003e\n\u003ch3 data-start=\"3300\" data-end=\"3331\"\u003eVariants and filter types\u003c\/h3\u003e\n\u003cp data-start=\"3333\" data-end=\"3464\"\u003eThis product page represents a generic pressure rated filter housing manufactured to AD 2000 HP0. The housing can be configured as:\u003c\/p\u003e\n\u003cul data-start=\"3465\" data-end=\"3612\"\u003e\n\u003cli data-start=\"3465\" data-end=\"3487\"\u003e\n\u003cp data-start=\"3467\" data-end=\"3487\"\u003ebag filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3488\" data-end=\"3513\"\u003e\n\u003cp data-start=\"3490\" data-end=\"3513\"\u003ebasket filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3514\" data-end=\"3539\"\u003e\n\u003cp data-start=\"3516\" data-end=\"3539\"\u003ecandle filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3540\" data-end=\"3566\"\u003e\n\u003cp data-start=\"3542\" data-end=\"3566\"\u003emodular filter housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3567\" data-end=\"3612\"\u003e\n\u003cp data-start=\"3569\" data-end=\"3612\"\u003efilter housing with quick release closure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3614\" data-end=\"3617\"\u003e\n\u003ch3 data-start=\"3619\" data-end=\"3652\"\u003eConfiguration and quotation\u003c\/h3\u003e\n\u003cp data-start=\"3654\" data-end=\"3762\"\u003eFilter housings manufactured to AD 2000 HP0 are supplied on a quotation basis. This allows configuration of:\u003c\/p\u003e\n\u003cul data-start=\"3763\" data-end=\"3911\"\u003e\n\u003cli data-start=\"3763\" data-end=\"3786\"\u003e\n\u003cp data-start=\"3765\" data-end=\"3786\"\u003efilter housing type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3787\" data-end=\"3822\"\u003e\n\u003cp data-start=\"3789\" data-end=\"3822\"\u003edesign pressure and temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3823\" data-end=\"3853\"\u003e\n\u003cp data-start=\"3825\" data-end=\"3853\"\u003edimensions and connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3854\" data-end=\"3872\"\u003e\n\u003cp data-start=\"3856\" data-end=\"3872\"\u003ematerial grade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3873\" data-end=\"3911\"\u003e\n\u003cp data-start=\"3875\" data-end=\"3911\"\u003einspection and documentation level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3913\" data-end=\"4026\"\u003eThis ensures the filter housing fully complies with the technical and regulatory requirements of the application.\u003c\/p\u003e\n\n  \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does AD 2000 HP0 mean for a filter housing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"AD 2000 HP0 is a German pressure vessel code that defines rules for the design, manufacture and testing of pressure equipment. A filter housing manufactured to AD 2000 HP0 is suitable for operation under defined pressure conditions.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is an AD 2000 HP0 filter housing pressure certified?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. A filter housing manufactured to AD 2000 HP0 is designed and built as pressure equipment and includes documented calculations, inspections and pressure testing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which filter types can be manufactured to AD 2000 HP0?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Filter housings manufactured to AD 2000 HP0 can be supplied as bag filters, basket filters, candle filters, modular housings or housings with quick release closure.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which industries require AD 2000 HP0 filter housings?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"These filter housings are commonly used in chemical processing, industrial filtration under pressure, utilities, plant engineering and process industries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can AD 2000 HP0 filter housings be custom manufactured?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Filter housings manufactured to AD 2000 HP0 are typically engineered to order, allowing customization of size, pressure rating, materials and connection types.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Filtra International","offers":[{"title":"Bag filter housing","offer_id":55771743748422,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Basket filter housing","offer_id":55771743781190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Candle filter housing","offer_id":55771743813958,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Modular filter housing","offer_id":55771743846726,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Filter housing with quick release closure","offer_id":55771743879494,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/2985\/6326\/files\/FilterHousingtoAD-2000HP0.png?v=1766098632"},{"product_id":"filter-housing-to-iso-3834-3","title":"Filter Housing Manufactured to ISO 3834-3","description":"\u003ch2 data-start=\"476\" data-end=\"500\"\u003eProduct description\u003c\/h2\u003e\n\u003ch3 data-start=\"502\" data-end=\"588\"\u003eFilter housing manufactured according to ISO 3834-3 welding quality requirements\u003c\/h3\u003e\n\u003cp data-start=\"590\" data-end=\"823\"\u003eThis filter housing is manufactured according to ISO 3834-3 welding quality requirements and is intended for industrial liquid filtration applications where controlled fabrication quality and reliable welding processes are essential.\u003c\/p\u003e\n\u003cp data-start=\"825\" data-end=\"1256\"\u003eISO 3834-3 defines quality requirements for fusion welding of metallic materials. It ensures that welding procedures, personnel qualification and production controls are managed according to a recognized European standard. This makes the filter housing suitable for applications where consistent workmanship and documented welding quality are required, without the need for pressure vessel certification under PED, AD 2000 or ASME.\u003c\/p\u003e\n\u003cp data-start=\"1258\" data-end=\"1437\"\u003eThe filter housing can be configured for a wide range of filtration tasks and is manufactured to order based on process conditions, material selection and connection requirements.\u003c\/p\u003e\n\u003chr data-start=\"1439\" data-end=\"1442\"\u003e\n\u003ch3 data-start=\"1444\" data-end=\"1492\"\u003eManufacturing standard and quality control\u003c\/h3\u003e\n\u003cp data-start=\"1494\" data-end=\"1612\"\u003eManufacturing to ISO 3834-3 focuses on controlled welding processes and traceability during production. This includes:\u003c\/p\u003e\n\u003cul data-start=\"1613\" data-end=\"1746\"\u003e\n\u003cli data-start=\"1613\" data-end=\"1645\"\u003e\n\u003cp data-start=\"1615\" data-end=\"1645\"\u003equalified welding procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1679\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1679\"\u003etrained and qualified welders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1680\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1682\" data-end=\"1714\"\u003edocumented production controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1715\" data-end=\"1746\"\u003e\n\u003cp data-start=\"1717\" data-end=\"1746\"\u003einspection of welded joints\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1748\" data-end=\"1906\"\u003eThis standard is commonly used for industrial equipment that requires proven welding quality but does not fall under mandatory pressure equipment regulations.\u003c\/p\u003e\n\u003chr data-start=\"1908\" data-end=\"1911\"\u003e\n\u003ch3 data-start=\"1913\" data-end=\"1943\"\u003eDesign and configuration\u003c\/h3\u003e\n\u003cp data-start=\"1945\" data-end=\"2178\"\u003eThe filter housing is designed as a modular solution and can be configured to suit different filtration principles and installation requirements. Depending on the application, the housing can be supplied in various designs and sizes.\u003c\/p\u003e\n\u003cp data-start=\"2180\" data-end=\"2220\"\u003eTypical configurable parameters include:\u003c\/p\u003e\n\u003cul data-start=\"2221\" data-end=\"2361\"\u003e\n\u003cli data-start=\"2221\" data-end=\"2252\"\u003e\n\u003cp data-start=\"2223\" data-end=\"2252\"\u003ehousing diameter and length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2253\" data-end=\"2288\"\u003e\n\u003cp data-start=\"2255\" data-end=\"2288\"\u003econnection type and orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2289\" data-end=\"2307\"\u003e\n\u003cp data-start=\"2291\" data-end=\"2307\"\u003esealing system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2308\" data-end=\"2342\"\u003e\n\u003cp data-start=\"2310\" data-end=\"2342\"\u003einternal filter element design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2343\" data-end=\"2361\"\u003e\n\u003cp data-start=\"2345\" data-end=\"2361\"\u003esurface finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2363\" data-end=\"2492\"\u003eThe design allows the filter housing to be integrated into existing systems or supplied as part of a new filtration installation.\u003c\/p\u003e\n\u003chr data-start=\"2494\" data-end=\"2497\"\u003e\n\u003ch3 data-start=\"2499\" data-end=\"2530\"\u003eMaterials of construction\u003c\/h3\u003e\n\u003cp data-start=\"2532\" data-end=\"2827\"\u003eFilter housings manufactured to ISO 3834-3 are typically produced in stainless steel or carbon steel, depending on the chemical compatibility and process conditions. Material selection is defined during the quotation phase to ensure suitability for the filtered medium and operating environment.\u003c\/p\u003e\n\u003chr data-start=\"2829\" data-end=\"2832\"\u003e\n\u003ch3 data-start=\"2834\" data-end=\"2852\"\u003eKey benefits\u003c\/h3\u003e\n\u003cul data-start=\"2854\" data-end=\"3180\"\u003e\n\u003cli data-start=\"2854\" data-end=\"2923\"\u003e\n\u003cp data-start=\"2856\" data-end=\"2923\"\u003eManufactured according to ISO 3834-3 welding quality requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2924\" data-end=\"2971\"\u003e\n\u003cp data-start=\"2926\" data-end=\"2971\"\u003eControlled and documented welding processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2972\" data-end=\"3033\"\u003e\n\u003cp data-start=\"2974\" data-end=\"3033\"\u003eFlexible design suitable for multiple filtration concepts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3034\" data-end=\"3066\"\u003e\n\u003cp data-start=\"3036\" data-end=\"3066\"\u003eCustom manufactured to order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3067\" data-end=\"3118\"\u003e\n\u003cp data-start=\"3069\" data-end=\"3118\"\u003eSuitable for industrial filtration applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3119\" data-end=\"3180\"\u003e\n\u003cp data-start=\"3121\" data-end=\"3180\"\u003eIdeal where pressure vessel certification is not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3182\" data-end=\"3185\"\u003e\n\u003ch3 data-start=\"3187\" data-end=\"3213\"\u003eTypical applications\u003c\/h3\u003e\n\u003cp data-start=\"3215\" data-end=\"3258\"\u003eThese filter housings are commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3259\" data-end=\"3442\"\u003e\n\u003cli data-start=\"3259\" data-end=\"3291\"\u003e\n\u003cp data-start=\"3261\" data-end=\"3291\"\u003eindustrial liquid filtration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3292\" data-end=\"3327\"\u003e\n\u003cp data-start=\"3294\" data-end=\"3327\"\u003echemical and process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3328\" data-end=\"3357\"\u003e\n\u003cp data-start=\"3330\" data-end=\"3357\"\u003ewater and utility systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3358\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3360\" data-end=\"3394\"\u003erecycling and recovery processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3395\" data-end=\"3442\"\u003e\n\u003cp data-start=\"3397\" data-end=\"3442\"\u003egeneral industrial filtration installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3444\" data-end=\"3447\"\u003e\n\u003ch3 data-start=\"3449\" data-end=\"3480\"\u003eVariants and filter types\u003c\/h3\u003e\n\u003cp data-start=\"3482\" data-end=\"3625\"\u003eThis product page represents a generic filter housing manufactured to ISO 3834-3. Specific filter types can be selected as variants, including:\u003c\/p\u003e\n\u003cul data-start=\"3626\" data-end=\"3778\"\u003e\n\u003cli data-start=\"3626\" data-end=\"3649\"\u003e\n\u003cp data-start=\"3628\" data-end=\"3649\"\u003ebag filter housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3650\" data-end=\"3676\"\u003e\n\u003cp data-start=\"3652\" data-end=\"3676\"\u003ebasket filter housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3677\" data-end=\"3703\"\u003e\n\u003cp data-start=\"3679\" data-end=\"3703\"\u003ecandle filter housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3704\" data-end=\"3731\"\u003e\n\u003cp data-start=\"3706\" data-end=\"3731\"\u003emodular filter housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3732\" data-end=\"3778\"\u003e\n\u003cp data-start=\"3734\" data-end=\"3778\"\u003efilter housings with quick release closure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3780\" data-end=\"3783\"\u003e\n\u003ch3 data-start=\"3785\" data-end=\"3818\"\u003eConfiguration and quotation\u003c\/h3\u003e\n\u003cp data-start=\"3820\" data-end=\"3932\"\u003eFilter housings manufactured to ISO 3834-3 are supplied on a quotation basis. This allows full customization of:\u003c\/p\u003e\n\u003cul data-start=\"3933\" data-end=\"4038\"\u003e\n\u003cli data-start=\"3933\" data-end=\"3956\"\u003e\n\u003cp data-start=\"3935\" data-end=\"3956\"\u003efilter housing type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3957\" data-end=\"3987\"\u003e\n\u003cp data-start=\"3959\" data-end=\"3987\"\u003edimensions and connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3988\" data-end=\"4006\"\u003e\n\u003cp data-start=\"3990\" data-end=\"4006\"\u003ematerial grade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4007\" data-end=\"4025\"\u003e\n\u003cp data-start=\"4009\" data-end=\"4025\"\u003esealing system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4026\" data-end=\"4038\"\u003e\n\u003cp data-start=\"4028\" data-end=\"4038\"\u003equantity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4040\" data-end=\"4142\"\u003eThis ensures the filter housing matches the technical and operational requirements of the application.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does ISO 3834-3 mean for a filter housing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"ISO 3834-3 defines quality requirements for welding processes. A filter housing manufactured to ISO 3834-3 is produced using controlled welding procedures with qualified personnel and documented production controls.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is a filter housing manufactured to ISO 3834-3 pressure certified?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. ISO 3834-3 is a welding quality standard and not a pressure vessel certification. It applies to the manufacturing process rather than pressure equipment approval.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which filter types are available under this standard?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Filter housings manufactured to ISO 3834-3 can be supplied as bag filters, basket filters, candle filters, modular housings or housings with quick release closure.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which industries use ISO 3834-3 filter housings?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"These filter housings are used in general industrial filtration, chemical processing, water treatment, recycling and utility applications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can ISO 3834-3 filter housings be custom manufactured?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Filter housings manufactured to ISO 3834-3 are typically produced to order, allowing customization of size, connections, materials and internal filter design.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Filtra International","offers":[{"title":"Bag filter housings","offer_id":55761331257670,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Basket filter housings","offer_id":55761331290438,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Cartridge filter housings","offer_id":55761331323206,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Modular filter housings","offer_id":55761331355974,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"Filter housings with quick release closure","offer_id":55761331388742,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/2985\/6326\/files\/FilterHousingtoISO3834-3.png?v=1766098711"}],"url":"https:\/\/filtrainternational.com\/collections\/heavy-duty-filter-housing.oembed","provider":"Filtra International","version":"1.0","type":"link"}